| Technical Parameters | |||||||||||
| Electrical parameters | |||||||||||
| Inverter Device inputout | Model SP-PV | 1.0KW | 2.0KW | 3.0KW | 4.0KW | 5.0KW | 6.0KW | 8.0KW | 10.0KW | 12.0KW | |
| rated power | 1.0KW | 2.0KW | 3.0KW | 4.0KW | 5.0KW | 6.0KW | 8.0KW | 10.0KW | 12.0KW | ||
| Peak power (2 seconds) | 3.0KW | 6.0KW | 9.0KW | 12.0KW | 15.0KW | 18.0KW | 24.0KW | 30.0KW | 36.0KW | ||
| Output voltage waveform | Pure sine wave (mains or generator) | ||||||||||
| Rated efficiency | >88%(Peak) | ||||||||||
| Online Mode Efficiency | >95% | ||||||||||
| Power Factor | 0.9-1.0 | ||||||||||
| Rated output voltage | 100-110-120Vac /220-230-240Vac | ||||||||||
| Output frequency | 50Hz ±0.3Hz/60Hz ±0.3Hz | ||||||||||
| Short circuit protection | Yes, short circuit protection after 1 second | ||||||||||
| Typical switching time | 10ms(max) | ||||||||||
| Total Harmonic Distortion | <10% | ||||||||||
| DCenter | Rated input voltage | 12.0Vdc /24.0Vdc/48.0Vdc | 24.0Vdc /48.0Vdc | 48.0Vdc/60.0Vdc/72.0Vdc | |||||||
| Minimum starting voltage | 10.0Vdc /10.5Vdc for12Vdc Mode | *2 for 24Vdc,*4 for 48Vdc*5 | |||||||||
| Low battery voltage alarm | 10.5Vdc /11.0Vdc for12Vdc Mode | 60VdcVdc *672Vdc | |||||||||
| Low voltage cut-out | 10.0Vdc /10.5Vdc for12Vdc Mode | ||||||||||
| High voltage cutting | 16.0Vdc for 12Vdc Mode | ||||||||||
| Low voltage recovery | 15.5Vdc for 12Vdc Mode | ||||||||||
| Charge controlDevice | The output voltage | Depends on battery type | |||||||||
| Charging circuit breaker specifications | 15A | 20A | 30A | 40A | 40A | 40A | 50A | 80A | 80A | ||
| Maximum charging current | See detailed table | ||||||||||
| Starting voltage | 10.5 -15.7Vdc for12Vdc Mode | *2 for 24Vdc,*4 for 48Vdc;*672Vdc | |||||||||
| Overcharge protection cut-off point | Greater than 15.8Vdc for 12Vdc Mode | ||||||||||
| Protect | Rated input voltage | 100-110-120Vac /220-230-240Vac | |||||||||
| Maximum input voltage | 150VAC For 120Vac LV Mode;300VAC For 230Vac HV Mode; | ||||||||||
| Rated input frequency | 50Hz or 60Hz | ||||||||||
| Low frequency cut-out | 47±0.3Hz for 50Hz,57±0.3Hz for 60Hz | ||||||||||
| High frequency cut-out | 55±0.3Hz for 50Hz,65±0.3Hz for 60Hz | ||||||||||
| Overload protection | have | ||||||||||
| Output short circuit protection | have | ||||||||||
| Maximum bypass current | 30Amp | 40Amp | 80Amp | ||||||||
| sun Controllable Deviceparameter | Solar system voltage | MPPT12V/24V/36V/48V automatic identification | |||||||||
| Photovoltaic panel open circuit voltage | 18~150Vdc@12V 35~150Vdc@24V60~150Vdc@48V | ||||||||||
| Rated charging current | 30A-120A (optional) | ||||||||||
| Charging efficiency | 97.6% | ||||||||||
| Rechargeable battery type | Valve Regulated Lead Acid Battery Gel Battery Lithium Battery | ||||||||||
| charging method | Four-stage charging: constant current charging, constant voltage charging, floating charging, equalizing charging | ||||||||||
| safety protection | Solar panel short circuit protection, overcharge protection, over discharge protection, overload protection | ||||||||||
| mechanicalparameter | Install | Wall Mount | |||||||||
| Inverter size (length*width*high) | 340*420*200mm | 425*375*200mm | 560*420*235mm | 655*490*240mm | |||||||
| Inverter housing size(Length*Width*Height) | 415*440*300mm | 500*495*300mm | 660*470*310mm | 720*470*290mm | |||||||
| Inverter with solar powerNet weight KG | 16 | 20 | 26.5 | 31.5 | 33.5 | 37.5 | 56.5 | 58.5 | 61.5 | ||
| Package includes solar panelNet weight KG | 19 | 29.5 | 38 | 40 | 44 | 63.5 | 66 | 68.5 | 70.5 | ||
| show | Status LEDs / Status LEDs+LCD | ||||||||||
| Standard warranty | 2 years | ||||||||||