| Electrical Specifications | ||||||||
| Model(HC) | 1kw | 1.5kw | 2kw | 3kw | 4kw | 5KW | 6KW | |
| Rated output power(W) | 1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W | |
| Rated input voltage | 12VDC/24VDC/48VDC | 12VDC/24VDC/48VDC | 24VDC/48VDC | |||||
| Mains mode specifications: | ||||||||
| Input voltage waveform | Sine wave (mains or generator) | |||||||
| Rated input voltage | 100V/110V/120V/220V/230V/240Vac | |||||||
| Low voltage cut-off point | 92/184Vac±4% | |||||||
| Low pressure recovery point | 97/194Vac ±4% | |||||||
| High voltage cut-off point | 127/253Vac±4% | |||||||
| High voltage recovery point | 121/243Vac±4% | |||||||
| Maximum AC input voltage | 135/270V rms | |||||||
| Rated input frequency | 50Hz/60Hz (auto detection) | |||||||
| Low voltage recovery point frequency | 40.5±0.3Hz; | |||||||
| Low voltage cut-off frequency | 40±0.3Hz; | |||||||
| High voltage recovery point frequency | 69.5±0.3Hz; | |||||||
| High voltage cut-off frequency | 70±0.3Hz ; | |||||||
| Output voltage waveform | Consistent with input voltage waveform | |||||||
| Overload protection | Circuit breaker start | |||||||
| Short circuit protection | Circuit breaker start | |||||||
| Power Efficiency | >95% | |||||||
| Converting current | 30A | |||||||
| Conversion time (Ac to Dc) | 10ms | |||||||
| Conversion time (Dc to Ac) | 10ms | |||||||
| Bypass switching current | have | |||||||
| Bypass maximum load current | 30A | |||||||
| Output voltage waveform | Sine Wave | |||||||
| Power Factor | 0~1.0 | |||||||
| Rated output voltage(V) | 120/230Vac | |||||||
| Rated output frequency(Hz) | 60/50Hz ±0.3Hz | |||||||
| Automatically track main frequency (Hz) | Yes (from the first connection) | |||||||
| Output voltage range | ±2%rms | |||||||
| efficiency | >80% | |||||||
| Overload protection (SMPS load) | (110%<load<125%)± 10%: Disconnect output voltage after 15 minutes (125%<load<150 %)±1 0%: disconnect output voltage after 10 seconds Load > 150% ± 10%: disconnect output voltage after 20 seconds | |||||||
| Peak capacity (10s) | 3000VA | 4500VA | 6000VA | 9000VA | 1200VA | 15000VA | 18000VA | |
| start the motor | 1HP | 1.5HP | 2HP | 3HP | 4HP | 5HP | 6HP | |
| Short circuit protection | Current limit (power off after 10s) | |||||||
| Circuit breaker size | 15A | 20A | 30A | 40A | ||||
| Rated DC input voltage | 12V/24V/48V | |||||||
| Minimum DC terminal voltage | 10V/20V/40V | |||||||
| Undervoltage warning | 10.5Vdc ±0.3Vdc (12V power supply) | |||||||
| The DC input voltage is too low. Automatic power-off | 10.0Vdc ±0.3Vdc (12V power supply) | |||||||
| Input overvoltage warning and power off | 16Vdc ±0.3Vdc (12V power supply) | |||||||
| Input overvoltage recovery | 15.5Vdc ±0.3Vdc (12V power supply) | |||||||
| Power saving | Load ≤2W | |||||||
| Inverter dimensions (Length*Width*Height) | 360*185*180mm | 420*185*180mm | 597*195*190mm | |||||
| Packing size (length*width*height) | 520*315*305 | 580*315*305mm | 760*325*310mm | |||||
| Inverter weight | 13.5KG | 14KG | 17KG | 21KG | 27KG | 29.5KG | 30.5KG | |
| Package running weight | 15.5KG | 15.5KG | 19KG | 23.5KG | 29.5KG | 31.5KG | 32.5KG | |
| Standard warranty | 2 years | |||||||